Missing or Outdated Parameters or Parameter Values

Problem

In an existing project, you discover missing or outdated parameters or parameter values, for example via the properties of a component after a pipe network calculation or due to missing or outdated values in placed labels.

Cause: Obsolete Parameters on Components

The parameter names and/or parameter definitions of the components in your existing project do not match the parameters currently used in the LINEAR software.

Solution

  1. Calculate the pipe network and then navigate to Analyse TabLabeling ....
  2. In the Labeling dialog, click on Create Parameters in Network Components.

This function writes the determined parameter values to the components of the pipe network and updates all parameter names and definitions. Family parameters that are defined differently are replaced. Family parameters with a new name and project parameters are added. Obsolete parameters remain on the component, but are no longer taken into account and can be removed manually if necessary.

Cause: Obsolete Parameters in the Label Family

You are using obsolete parameter names or definitions in your custom labels.

Solution

  1. Navigate to the Revit-RibbonLINEARAdministrationDrop-down List: Show Parameter File to ensure that you are using the latest parameter file.
  2. Open the faulty custom label family and check whether modified or renamed parameters are used. Use the following tables for this purpose:
Table 1. Replaced Parameters
Old Parameter New Parameter
Cooling Discipline
LIN_CO_ELEMENT_NAME LIN_AN_ELEMENT_NAME
LIN_CO_ELEMENT_MANUFACTURER_NAME LIN_AN_MANUFACTURER
LIN_CO_SURROUNDING_PIPERUNNAME LIN_PIPE_RUN_NAME
LIN_CO_SURROUNDING_STOREYNAME LIN_FLOOR_NAME
Heating Discipline
LIN_HT_ELEMENT_NAME LIN_AN_ELEMENT_NAME
LIN_HT_ELEMENT_ARTICLE_NUMBER LIN_AN_ARTICLE_NUMBER
LIN_HT_ELEMENT_MANUFACTURER_NAME LIN_AN_MANUFACTURER
LIN_HT_SURROUNDING_PIPERUNNAME LIN_PIPE_RUN_NAME
LIN_HT_SURROUNDING_ROOMNAME LIN_ROOM_NAME
LIN_HT_SURROUNDING_STOREYNAME LIN_FLOOR_NAME
Discipline Potable Water
LIN_PW_ELEMENT_NAME LIN_AN_ELEMENT_NAME
LIN_PW_ELEMENT_ARTICLE_NUMBER LIN_AN_ARTICLE_NUMBER
LIN_PW_ELEMENT_MANUFACTURER_NAME LIN_AN_MANUFACTURER
LIN_PW_SURROUNDING_PIPERUNNAME LIN_PIPE_RUN_NAME
LIN_PW_SURROUNDING_ROOMNAME LIN_ROOM_NAME
LIN_PW_SURROUNDING_STOREYNAME LIN_FLOOR_NAME
Discipline Waste Water
LIN_WW_ELEMENT_NAME LIN_AN_ELEMENT_NAME
LIN_WW_ELEMENT_ARTICLE_NUMBER LIN_AN_ARTICLE_NUMBER
LIN_WW_ELEMENT_MANUFACTURER_NAME LIN_AN_MANUFACTURER
LIN_WW_SURROUNDING_PIPERUNNAME LIN_PIPE_RUN_NAME
LIN_WW_SURROUNDING_ROOMNAME LIN_ROOM_NAME
LIN_WW_SURROUNDING_STOREYNAME LIN_FLOOR_NAME
Discipline Ventilation
LIN_VE_ELEMENT_NAME LIN_AN_ELEMENT_NAME
LIN_VE_ELEMENT_ARTICLE_NUMBER LIN_AN_ARTICLE_NUMBER
LIN_VE_ELEMENT_MANUFACTURER_NAME LIN_AN_MANUFACTURER
LIN_VE_POWER_HUMIDIFIER LIN_VE_HUMIDIFIER_CAPACITY
LIN_VE_ZETA LIN_VE_ZETA_VALUE
Discipline Gas
LIN_GS_ELEMENT_NAME LIN_AN_ELEMENT_NAME
LIN_GS_ELEMENT_ARTICLE_NUMBER LIN_AN_ARTICLE_NUMBER
LIN_GS_ELEMENT_MANUFACTURER_NAME LIN_AN_MANUFACTURER
Table 2. Changed Parameters
Cooling Discipline
LIN_CO_MASSFLOWRATE
LIN_CO_MANIFOLD_NUMBER
LIN_CO_ADDITIONAL_KV_VALUE
LIN_CO_KV_VALUE
LIN_CO_KV_VALUE_PRIMARY
LIN_CO_KV_VALUE_RTV
LIN_CO_KV_VALUE_SECONDARY
LIN_CO_KV_VALUE_TARGET
LIN_CO_KV_VALUE_THV
Heating Discipline
LIN_HT_ELEMENT_DN
LIN_HT_ELEMENT_DN_RTV
LIN_HT_ELEMENT_DN_THV
LIN_HT_MASSFLOWRATE
LIN_HT_MASSFLOWRATE_PEAK
LIN_HT_MASSFLOWRATE_SUM
LIN_HT_MASSFLOWRATE_SUPPLEMENT_PRIMARY
LIN_HT_ELEMENT_NUMBER
LIN_HT_FLOWPATH_NUMBER
LIN_HT_LEG_NUMBER
LIN_HT_MANIFOLD_NUMBER
LIN_HT_ADDITIONAL_KV_VALUE
LIN_HT_KV_VALUE
LIN_HT_KV_VALUE_PRIMARY
LIN_HT_KV_VALUE_RTV
LIN_HT_KV_VALUE_SECONDARY
LIN_HT_KV_VALUE_TARGET
LIN_HT_KV_VALUE_THV
Discipline Potable Water
LIN_PW_FLOWPATH_NUMBER
LIN_PW_LEG_NUMBER
LIN_PW_MASSFLOWRATE_PWH_C
LIN_PW_MASSFLOWRATE
LIN_PW_ELEMENT_NUMBER
LIN_PW_CIRC_KV_VALUE
LIN_PW_KV_VALUE
LIN_PW_KV_VALUE_PWC
LIN_PW_KV_VALUE_PWH
Discipline Waste Water
LIN_WW_ELEMENT_NUMBER
LIN_WW_FLOWPATH_NUMBER
LIN_WW_LEG_NUMBER
Discipline Ventilation
LIN_VE_ELEMENT_NUMBER
LIN_VE_TS_NUMBER
Discipline Gas
LIN_GS_ELEMENT_NUMBER
LIN_GS_FLOWPATH_NUMBER
LIN_GS_LEG_NUMBER
LIN_GS_PRESSURE_GRADIENT
Product Data
LIN_PR_CVS_VALUE
LIN_PR_KVS_VALUE