Jump directly to main navigation Jump directly to content

Save and Update Parameters in Network Components

Shows step-by-step how to save selected parameters in network components.

Before you begin

You want to save selected parameters in network components or update network component parameters so that they can be retrieved and used, for example, when passing them on to other project participants.

Requirement:

The pipe or duct network is completely detected and calculated.

Navigate to:

Project tabDisciplineAnalyse tabLabeling...Configure export parameters

Applies to all disciplines.

Export parameter Revit

Procedure

  1. In the row of the network component to be edited, click on Three point button Configure parameters for export.

    The Configure Export Parameters dialog opens.

    Configure export parameter Revit
  2. Activate or deactivate the desired parameters for the selected network component and click OK.
    Note: A number of parameters are preselected by default for each component type.
  3. In the Labeling dialog, click on Create Parameters in Network Components to write the selected parameters to the network component and confirm the following prompt with Yes.
  4. If you change values or units of network component parameters, you must perform the calculation again and then exit the calculation dialog by clicking OK so that the updated values are saved in the components.

Results

The parameters were written to the network components as configured.

Parameter network component Revit