Details on Material in the Settings Waste Water
Information about the Material tab in the Settings dialog in the Pipe Network Calculation Waste Water.
You are here:
Tolerance between two bends or branch/bend
Minimum pipe length from which a pipe section is included in the parts list. If a pipe between bends or branches is shorter than the set minimum length, the pipe section is not listed in the parts list. The proposed length of 141mm corresponds to the drawn standard chamfer of 100mm.
Distance between roof drain and bend
Maximum distance for connection bends with short construction type. If the distance between the roof outlet and the bend is smaller than specified, a short type connecting bend is included in the parts list, if it is available with the selected pipe system.
Layer for fixing material
Opens the Select layer dialog where you can specify on which layer the mounting material is to be drawn. This creates a connection between drawn fixing and the material.
Reducing pieces eccentric
Enabled: Reducing parts for all siphonic pipe section parts are issued eccentrically. You can additionally set this option separately for each siphonic pipe section part in the calculation dialog.
Radius to remove guide brackets next to anchor points
For fixing pipes, you can determine the radius in which a superfluous plain bearing should be removed in the near fixed bearings.