Jump directly to main navigation Jump directly to content

Details on General in the Settings Waste Water

Information about the General tab in the Settings dialog in the Pipe Network Calculation Waste Water.

In this tab, specify global settings for the detection of components and pipes that are to be considered during calculation. The settings are saved with the project.

You are here:

Project tabDiscipline Waste waterPlanning typeAnalyse tabSettings ...General

General tab in the Wastewater settings in the LINEAR Solutions for Autodesk AutoCAD

Layer

The layers are preset according the program specifications. The program recognizes different types of pipes, by the layer on which these pipes have been drawn.

Also detect 3D layers

Enabled: 3D pipes from the Design 3D Pipe&Power module are also included in the calculation.

Disabled: 3D pipes from the Design 3D Pipe&Power module are not included in the calculation.

Symbols, Waste/rainwater..., Ventilation..., Texts...

Clicking one of the buttons in the layer selection opens the Select Layer dialog, where you can specify on which layers the respective elements are located.

Component detection

Component selection

Dropdown list with the options for component selection:

  • Detect all components: The entire pipe network with all components is detected and taken into account in the calculation.

  • Detect partial network: If you select the Detect partial network option, the dialog is minimized and you can select the desired partial network with the mouse in the current view. You can select or deselect the corresponding components individually with a selection frame or with the mouse pointer. Confirm the selection of the components with Enter. The number of detected components is displayed after selection.

    If you start the calculation after selecting Detect partial network, the program asks you to reconfirm the selected components for the partial network. You have the possibility to change the selection of the components again or to start the calculation with the currently selected partial network by pressing the Enter key. An error-free calculation is only possible if the selected partial network is self-contained.

    : Allows to reselect a subnet in the current view. This button is only activated if you have selected the option Detect partial network and have already made a component selection.

    : Selects the selected partial network in the current view. This button is only active if you have selected the option Detect partial network and have already made a component selection.

Search radius

The search radius specifies up to which value distances between components, if any, created during drawing, are tolerated when calculating the network. This function prevents inaccuracies in the drawing of component connections in the millimeter range from being detected as open ends and thus as errors during the calculation.

Pipes in the Scheme

When setting up this section, keep in mind that a pipe network in the form of a pipe run scheme is only partially scalable at most. Edit the corresponding section directly in the calculation dialog to calculate the change in pipe lengths of a section part.

Enabled: The drawn pipe lengths and heights are determined during detection and multiplied by the entered factor. Since drawing is usually done at a scale of 1:1, the default factor is 1.

Disabled: The drawn pipe lengths and heights are determined during detection. If you have already edited section part data in the calculation dialog, the user-defined values are used.

Planning type

The current Planning type is displayed, which you define in the Disciplines ... section. The program derives the Z-axis for the determination of heights from the selected planning type.

Other settings

Detect material with every calculation

Enabled: For parts list output, the pipe material used will be calculated with each calculation.

Disabled: Calculation will be shortened since material will not be detected.

Refresh labeling when calculating

Enabled: If you made changes that affect calculation results, the labels in the project will be updated automatically with each calculation.

Disabled: The labels are updated only when you use the Refresh label command in the calculation dialog.

Display settings

: Opens the Display settings dialog where you can set the arrow size of the arrow pointing the selected component using the Show command in the calculation dialog. Furthermore, you can set if the view should be enlarged to the selected component/section part/flow path when displaying the component.