Details on Technical Data for Sewer Junction and the Partial Network End

Information about the technical data dialog for sewer junction and partial network end.

The sewer connection is used in the drainage network to mark where the waste water flows into the public sewage system. The sewer junction has one connecting point that is connected to a pipe. Simply add it at the end point of a pipe. When using a partial network end, the same dialog will open.

You are here:

Project tabDisciplineAnalyse tabComponentsTechnical data ...Component

Sewer junction Linear Revit

The sewer junction does not have any adjustable parameters besides the zeta value. You may, however, enter a name in order to discriminate individual sewer connections, for instance with regard to additional rainwater feed.

Name

Specifies the name of the component. You can modify the name. Clicking restores the default setting.

Calculation results

After the calculation, the following calculation results are displayed here as soon as the pipe network has been detected and values for the parameters are available:

Sewage water:

  • Number of connected kitchen drains

  • Number of connected toilets

  • ΣDU: Sum of connection values

  • Qww [l/s]: Sewage water flow rate

  • Qc [l/s]: Continuous flow rate

  • Qp [l/s]: Pump flow rate (if existing)

  • Qtot [l/s]: Total sewage water flow rate

  • Nominal diameter

Rainwater:

  • A: Connected roof area

  • Qr [l/s]: Rainwater flow rate

  • Nominal diameter