Jump directly to main navigation Jump directly to content

Editing Partial Sections

Shows step-by-step how to set calculation-relevant data for individual pipe sections.

Before you begin

You have calculated a pipe network and want to adjust or supplement the data of selected pipe sections.

Requirement:

The pipe network has been designed and calculated.

Note:

Values entered locally have priority over settings.

Navigate to:

Project tabDisciplines …Waste waterAnalyse tabCalculation …

Applies to Waster Water.

Procedure

  1. In the section Pipe sections, select the desired pipe section.
  2. Click on Edit....

    The Pipe section dialog opens.

  3. If required, select the Type of pipe for the respective section from the drop-down list.
  4. In the section Geometry, enter the desired gradient of the section, if necessary, deviating from the determined value.
  5. If you want to limit the Dimensions available for the design of this pipe section, enter the desired values under Minimum and Maximum.
  6. In the section Building data, select a suitable building type to assign a different discharge coefficient to the partial section.

Results

The adjusted data has been assigned to the selected pipe section and is used in the calculation.