Setting Limit Values for Switching Between Round and Rectangular Ducts
Shows step-by-step how to set limit values for switching between round and rectangular ducts during dimensioning.
Before you begin
You want to change the duct geometry automatically in the dimensioning from certain limit values.
Navigate to:
Applies to: Ventilation.
Procedure
- Open the section Duct dimensions with a click.
- Activate the Use oval duct option if oval ducts are also to be used in the dimensioning.
- In the drop-down lists, define the limit value from which the dimensioning is to switch to oval or rectangular channel.