Details on Visualization
Information about the Visualization dialog in the Pipe and Duct Network Calculation.
Have the calculation results and other properties of the pipe and duct network displayed in color in the drawing. The data is sorted into tabs, some of which are discipline-specific.
You are here:
Or:
Applies to: Heating, Potable water, Waste water, Ventilation, Cooling, Gas.
Selected system(s)
Drop-down list for selecting the system whose data is to be visualized.
Data
Shows the type of information that is colored in the drawing. The data types vary depending on the trade.
Data type
continuous: The data are displayed by a color transition between the upper (maximum) and lower (minim) value.
discrete: Data in evenly distributed valence intervals are assigned with preset colors in a fix sequence.
Unit
Shows the unit in which the visualization of the information is carried out.
Color assignment
For the continuous data type, you can select the colors for the upper and lower data value via ... .
Zoom extents
Enabled: During visualization, the whole drawing is shown.
Disabled: The visualization takes place in the currently shown drawing section.
Line weight (LW)
Enabled: When visualizing single-line pipes, the pipes are displayed with thick lines.
Disabled: When visualizing single-line pipes, the pipes are displayed with of the constructed line width.
Reset colors
Enabled: After finishing the visualization, the pipes or ducts are returned to their original color display.
Disabled: After finishing the visualization, the pipes or ducts keep the colors of the visualization. This way the color display of the visualization can be used in sheets.
Display
Starts the visualization of the selected information with the desired settings. A dialog opens where you can customize and filter the visualization in more detail. Pressing Esc brings you back to the Visualization dialog.