Labeling of Components in the Pipe and Duct Network Calculation
Shows step-by-step how to label components with the calculation and component data after calculating your pipe or duct network.
Before you begin
After calculating your pipe or duct network, you would like to label the components with the calculation and component data.
Requirement:
You have successfully performed the Pipe and Duct Network Calculation.
Navigate to:
Procedure
- Click Labeling .... Note: Before you label your components, you can customize the labels for the different network objects by selecting the button in the section Configure label section.The Labeling dialog opens.
- In the Labeling options section, select the settings for the labeling.
- Start the Labeling process by clicking Labeling..... Note: If you have selected the Manually option, the dialog closes and you can set the labelers manually by clicking the components. If you have selected the Automatically (only duct sections) option, the labeling of all components will be performed automatically with the labels that have been set. If you select the option Automatically incl. selection (only duct sections), the dialog closes and you have to select the section(s) for labeling and confirm the selection with Enter.
Results
You have placed the labelers with the data from the Pipe and Duct Network Calculation on the components.