Configuring Section Parts
Shows step-by-step how to configure the data of section parts.
Before you begin
You would like to set the section part data of your scheme for a pipe network calculation
Requirements:
Navigate to:
Applies to Heating, Potable water, Waste water and Gas.
![Scheme heating Linear AutoCAD scheme generator](https://knowledge.linear.eu/LS/V24/EN/AC/en/topics/../figures/neZe_schemagenHT_SMP.png)
Procedure
- In the scheme, click the section part you would like to edit. The Pipe run data dialog opens.
- In the Section area, specify the Length of the section part and the number of Additional bends.
- Optional: In the Nominal pipe diameter section, set the nominal diameters for the pipes in the section part.
- Use the
and
buttons to switch to the adjacent section parts and set their data.
The currently selected section part is shown dashed in the scheme. - Use the button
to switch to vertical tether feed pipes and set their data.
- Close the dialog with OK when you have set the data of all section parts of your scheme.
Results
The section part data of the scheme are set.