Direkt zur Hauptnavigation springen Direkt zum Inhalt springen

Details on Components (Heating, Cooling)

Information aboout the Components section in the disciplines heating and cooling pipe network calculation.

You are here:

Project tabDiscipline Heating/CoolingAnalyse tabComponents

Applies to: Heating, Cooling.

Components heating cooling Linear Reivt

All settings specified in the section Components are saved in the components and pipes of the project.

Classify ...

Opens the Classify dialog after selecting components, in which the calculation types of the selected components are displayed. If required, you can also use this dialog to adjust the assigned calculation types and assign a calculation type to unclassified components.

Pipe material ...

After selecting pipes, this button opens the dialog Pipe tables, where you can assign pipe material to the selected pipes.

Technical data …

After selecting a component, this button opens the corresponding component dialog, in which technical data relevant for the calculation for that particular component can be entered.

Connections ...

If during the calculation you have used manufacturer pipe material, this button will be activated. You can assign connectors to components to have appropriate manufacturer connector pieces listed in the parts list.

Copy <

Copies the technical data from the component dialogs and the lengths of edited pipes if the corresponding checkboxes are activated.

First select the original component or pipe for which you want to copy the data. Then transfer the copied data to a selection of components or to all components of the same type.

Element

Description

Component data

Enabled: The component type, the technical data from the component dialogs and any assigned connections of the original component are copied. For pipes, the definition of the pipe materials is copied.

Lengths

Enabled: Edited lengths of pipes are copied.

for all components

Enabled: When copying, the data of the original component is copied for all components of the same type or all pipes.

Disabled: Select the components or pipes that will receive the copied data of the original component.

Reset <

Resets changed technical data or edited lengths of pipes if the corresponding checkboxes are activated. The reset can be carried out for all components of the same type or for a selection.

Element

Description

Component data

Enabled: The component type, the technical data from the component dialogs and any assigned connections of the original component are reset. For pipes, the definition of the pipe material is reset.

Lengths

Enabled: Edited lengths of pipes are reset.

for all components

Enabled: The data of all components of the same type or of all pipes are reset.

Disabled: Select the components or pipes whose data is to be reset.

Connect components <

Connects two components that are calculated in pairs, like regulating valve and shut-off valve, differential pressure closed-loop controller and differential pressure transducer or three-way valve with t-piece.