About Building Units and Ventilation Zones
Explains the concept for building units and ventilation zones.
A building unit (BU) is a part of a building used by a party, in which the party can individually control the heat supply. A room cannot be part of two building units. The settings for the building unit are not relevant in the heat load for Denmark.
A ventilation zone (VZ) consists of rooms that have a direct or indirect air connection due to their dimensioning. According to the dimensioning, there is no air exchange between ventilation zones. A room can therefore not be part of two ventilation zones.
Building | BU | VZ | Notes |
---|---|---|---|
One-family house | Project | Project | |
Multi family house, ventilation per apartment | Apartment | Apartment | Staircase no part of a BU |
Multi family house: Apartment over several storeys | Apartment | Apartment | Numbers and names of the connected apartment have to be identical. |
Multi family house, ventilation central | Apartment | Project | Staircase no part of a BU |
Shopping Mall | Area | Storey, project | Optional Atrium own area |
Shopping mall, two ventilation systems per storey for BU | Area | Storey | Division into building parts, create same storeys per building part |
Industrial building (hall and offices own VZ) | Project | Building part | Create different storeys per building part |
Office building (one company) | Project | Storey, project | |
Hospital | Project | Area |