Details on Technical Data for Sewer Junction or Partial Network End

Information on the technical data dialog for sewer junction and partial network end.

The sewer connection is used in the drainage network to mark where the waste water flows into the public sewage system. The sewer junction has one connecting point that is connected to a pipe. Simply add it at the end point of a pipe. When using a partial network end, the same dialog will open.

You are here:

Project tabDisciplineAnalyse tabComponentsTechnical data ...<Component

The sewer connection does not have parameters to be set. You may, however, enter a name in order to discriminate individual sewer connections, for instance with regard to additional rainwater feed. After the calculation, the following calculation results will be displayed here as soon as the pipe network is detected:

Sewage water:

  • Number of connected kitchen drains

  • Number of connected toilets

  • ΣDU: Sum of connection values

  • Qww [l/s]: Sewage water flow rate

  • Qc [l/s]: Continuous flow rate

  • Qp [l/s]: Pump flow rate (if existing)

  • Qtot [l/s]: Total sewage water flow rate

  • Nominal diameter

Rain water:

  • A: Connected roof area

  • Qr [l/s]: Rainwater flow rate

  • Nominal diameter