Details on Simulation Network Temperature
Information about the Simulation network temperature tab in the Ambience dialog of the calculation dialog for potable water.
You are here:
Temperature profile of a single pipe
After clicking this button you can select one single or two adjacent pipes whose temperature development is displayed in a temperature-time-diagram for comparison.
Temperature profile of entire pipe system referred to specified time period of
After entering the preset time and clicking , the achieved temperatures of the pipes are displayed in color in the drawing.
After which time will the preset temperature be attained?
After entering the preset temperature and clicking , the achieved temperatures of the pipes are displayed in color in the drawing.
Reset colors
Enabled: After exiting the visualization with Enter, the colors of the pipes in the drawing are reset to the medium color.
Disabled: After exiting the visualization with Enter, the colors of the visualization remain in the drawing and the representation can be used for printouts and for creating plans.
Pipe filter